Need More Information?

PM8315 TEMUX®
High Density T1/E1 Framer

Documents

> Are you seeing all your results?
If you are a PMC-Sierra Customer or Partner you may have permission to see additional results.
Please log in to display additional results.

Version Issue Date

Product Brief

PDFTEMUX High Density T1/E1 Framer with Integrated VT/TU Mapper and M13 Mux Short Form Data Sheet [53 kB] PMC-1971264 2001-08-03 

Reference Design

Locked Document, Log In RequiredPDFAAL1gator-32/TEMUX DEVELOPMENT KIT [4.71 MB] PMC-1991144 2001-06-06 
Locked Document, Log In RequiredPDFFrame Relay Port Card Reference Design [8.74 MB] PMC-1990533 2000-12-20 
Locked Document, Log In RequiredPDFAAL1gator-32/TEMUX Development Kit Installation Guide [86 kB] PMC-2002199 2001-01-18 

Data Sheet

Locked Document, Log In RequiredPDFTEMUX High Density T1/E1 Framer with Integrated VT/TU Mapper and M13 Multiplexer Telecom Standard Product Register Descriptions [4.37 MB] PMC-1990495 2001-05-14 
Locked Document, Log In RequiredPDFHigh Density T1/E1 Framer with Integrated VT/TU Mapper and M13 Multiplexer Telecom Standard Product Data Sheet [2.95 MB] PMC-1981125 2001-05-23 

Application Note

Locked Document, Log In RequiredPDFConfiguring SBI Compatible Devices [551 KB] PMC-2020180 2007-11-20 
Locked Document, Log In RequiredPDFKnowledge Base Items for the PM8315 TEMUX [1.68 MB] PMC-2020397 n/a  2005-11-10 
Locked Document, Log In RequiredPDFSBI Configuration Between PM73122 AAL1gator™-32 and PM8315 TEMUX™ [513 kB] PMC-2001770 2001-05-03 
Locked Document, Log In RequiredPDFTEMUX/TEMAP/TECT3 Programmer?s Guide [964 kB] PMC-1991268 2001-11-28 
Locked Document, Log In RequiredPDFTechnical Overview of the High Density T1/E1 Framer with Integrated VT/TU Mapper and M13 Multiplexer Telecom Standard Product [229 kB] PMC-1981141 1999-06-01 

Errata

Locked Document, Log In RequiredPDFTEMUX Production Release Errata [137 KB] PMC-2011388 2004-12-17 
Locked Document, Log In RequiredPDFHigh Density T1/E1 Framer with Integrated VT/TU Mapper and M13 Multiplexer Telecom Standard Product Device Driver Errata [86 kB] PMC-2001481 2000-10-20 
Locked Document, Log In RequiredPDFTEMUX/TEMAP/TECT3 Production-Release Device Driver Errata [234 kB] PMC-2012654 2001-12-21 
Locked Document, Log In RequiredPDFAAL1GATOR-32/TEMUX Development Kit Errata [135 kB] PMC-2020039 2002-02-01 

Software Documentation

Locked Document, Log In RequiredPDFTEMUX High Density T1/E1 Framer with Integrated VT/TU Mapper and M13 Multiplexer Telecom Standard Product Register Descriptions [4.37 MB] PMC-1990495 2001-05-14 
Locked Document, Log In RequiredPDFTEMUX/TEMAP/TECT3 Driver Manual [596 kB] PMC-1991611 2001-08-03 

Software

Locked Document, Log In RequiredPDFTEMUX/TECT3/TEMAP Device Driver [111 kB] PMC-2000200 rel 1.0  2001-08-14 

White Papers

PDFDensity Solutions with TEMUX and FREEDM-84 [868 kB] PMC-1991202 1999-10-04 

Models

Locked Document, Log In RequiredPDFTEMUX [25 kB] 1.03  1999-08-16 

BSDL Files

Text / Binary FileBoundary Scan Description Language (BSDL) Source Code for the PM8315 TEMUX Device PMC-1990995 1999-08-11 

Features

  • Monolithic device which integrates 28 T1 framers, 21 E1 framers, a SONET/SDH VT1.5/V2/TU-11/TU-12 bit asyn-chronous mapper, a full featured M13 multiplexer with DS-3 framer, and a SONET/SDH DS-3 mapper for term-inating DS-3 multiplexed T1 streams, SONET/SDH mapped T1 streams or SONET/SDH mapped E1 streams.
  • Seven T1 modes of operation:
    1. Up to 28 T1 streams mapped as bit asynchronous VT1.5 virtual tributaries into a STS-1 SPE or TU-11 tributary units into a STM-1/VC3 or TUG3 from a STM-1/VC4.
    2. Single STS-1, AU3 or TUG3 Bit Asynchronous VT1.5 or TU-11 Mapper with ingress or egress link monitoring per T1 tributary.
    3. Up to 28 T1 streams M13 multiplexed into a serial DS-3.
    4. Up to 28 T1 streams M13 multiplexed into a DS-3; the DS-3 is asynchronously mapped into a STS-1/STM-2/STM-0 SPE.
    5. DS-3 M13 Multiplexer with ingress or egress link monitoring per T1 tributary.
    6. Up to 28 DS-3 multiplexed T1 streams are mapped as bit asynchronous VT1.5 virtual tributaries or TU-11 tributary units, providing a transmultiplexing function between DS-3 and SONET/SDH.
    7. Up to 21 T1 streams mapped as bit asynchronous VT2 virtual tributaries into a STS-1 SPE or TU-12 tributary units into a STM-1/VC3 or TUG3 from a STM-1/VC4.
  • Two E1 modes of operation:
    1. Up to 21 E1 streams mapped as bit asynchrounous VT2 virtual tributaries into a STS-1 SPE or TU-12 tributary units into a STM-1/VC3 or TUG3 from a STM-1/VC4.
    2. Single STS-1, AU3 or TUG3 Bit Asynchronous VT2 or TU-12 Mapper with ingress or egress per tributary link monitoring.
  • Supports a byte serial Scalable Bandwidth Interconnect (SBI) bus interface for high density system side device interconnection of up to 84 T1 streams, 63 E1 streams, three DS-3 streams or three E3 streams.
  • Up to 28 VT1.5/TU-11 or 21 VT2/TU-12 tributaries can be passed as transparent virtual tributaries (with pointer processing) between the SONET/SDH TelecomBus on the line side and the SBI bus on the system side.
  • Supports transfer of PCM data to/from 1.544 MHz and 2.048 MHz system-side devices. Also supports a fractional T1 or E1 system interface with independent ingress/egress Nx64 Kb/s rates. Supports a 2.048 MHz system-side interface for T1 mode without external clock gapping.
  • Supports 8 Mb/s MVIP on the system interface for all T1 or E1 links, a separate 8 Mb/s MVIP system interface for all T1 or E1 CAS channels and a separate 8 Mb/s MVIP system interface for all T1 or E1 CCS and V5.1/V5.2 channels.
  • Supports the M23 and C-bit parity DS-3 formats.
  • Supports stand-alone unchannelized DS-3 framer mode for access to the entire DS-3 payload. When configured to operate as a DS-3 Framer, gapped transmit and receive clocks can be optionally generated for interface to link layer devices which only need access to payload data bits.
  • Provides an on-board programmable binary pseudo-random sequence generator and detector for error testing at DS-3 rates and an on-board pseudo-random binary sequence generator and detector on each tributary for error testing at DS1, E1 or N*DS0 rates.

Applications

  • M13 Mux/Demux Equipment.
  • SONET-SDH Add/Drop and Terminal Multiplexers.
  • Integrated Services Platform.
 
 